Furnace Belt Lifetime Improvement
Furnace belts can fail due to oxidation, stretching, and carbon up-take. Minimox™ solution-coated and oxidized sections of 330-stainless furnace belt exhibit a protective barrier coating relative to uncoated sections. Material Interface is seeking a facility to test the Minimox™ coating on belt sections. All coatings will be furnished at no charge.
 |
 |
Uncoated belt section - flaking oxide after heating in air. |
Coated belt section - no flaking; protective barrier coating when heated in air. |
Spray coating the furnace belt with Minimox™ solution one time/day reduced oxidation mass gain of a 330 furnace belt by 60% at 850°C in air as shown in the graph below.
|